A SERVICE OF

logo

8
DOORS
The BMG/TMG cabinets have Anthony glass doors
that are equipped with a patented TorqueMaster
hinge system. The doors are easily adjusted using
a flathead screwdriver (Fig.3).
Figure 4
To remove the door shipping clamps,
remove the 4 shipping screws from the grill and
remove the screws from the clamps (Fig.4), and
replace grill.
SERVICE INSTRUCTIONS
1. High head pressure and high back pressure:
A. Condenser coil clogged or restricted
B. Condenser fan motor defective.
C. Air discharge in rear of cabinet restricted.
2. Low back pressure and low head pressure:
A. Restriction in system.
B. Refrigerant undercharged.
C. Leak in system
3. Pressure normal – cabinet warm:
A. Coil blocked with frost (see #4).
B. Refrigerant undercharged.
C. Control set too warm.
4. Cabinet not cycling – coil blocked with frost:
A. Defective temperature controller.
B. Refrigerant overcharged.
C. Location too hot.
D. Condenser clogged.
E. Condenser fan motor defective.
5. Compressor starts and runs – but cycles on overload:
A. Low voltage
B. Relay defective.
C. Overload defective.
D. High head pressure (see #1).
Tor
q
ue Ad
j
ustment
Levelin
g
Ad
j
ustment
Fi
g
ure 3