Locking Cup Modular Scaffold
Component Allowable Loads
Technical Manual
Section B
Rev.
Rated For Scaffold Use
Capacity of Locking Cup Horizontals
Part Number Vertical Post Spacing Allowable Center Load Allowable Uniform Load
0254-02-2036 3
’ 1,380 lbs. 920 lbs. / ft.
0254-02-2042 3
’ 6” 1,180 lbs. 675 lbs. / ft.
0254-02-2048 4
’ 1,040 lbs. 520 lbs. / ft.
0254-02-2060 5
’ 830 lbs. 330 lbs. / ft.
0254-02-2084 7
’ 595 lbs. 170 lbs. / ft.
3’ 3’ 6” 4’ 5’ 6’ 7’ 8’ 9’ 10’
3’ 306 262 230 184 153 131 115 102 92
3’ 6” 225 193 168 135 113 96 84 75 68
4’ 173 149 130 104 86 75 65 58 52
5
’ 110 94 83 66 55 47 41 37 33
7
’ 57 49 43 34 28 24 21 19 17
Length of
Bearer
Maximum Allowable Uniform Distributed Load Per Square Feet Area
Bay Length in Feet