2. System Overview
2.5.3 Control panel
Description
Image 2-9
Control panel
The control panel of the EPS8DE consists of
:
• Starting key (off / on / glow / start)
• Pilot lamp green (contact on / off), lamp lights up when contact on
• Pilot lamp red (charging current battery), lamp lights up when battery is not being charged
• Hours counter
• 1 fuse ( 2A ) hours counter
• Measuring unit , 3-fases for voltage, frequenc
y en current
• Voltage presence indicator ( 3-fases )
• 3 fuses ( 2 A ) for mentioned above
• Main breaker 25A 4p
• Earth leakage protection 40A 4p,300mA, class A
• 1 x breaker 16A 2p/C/10kA (electronics)
• 1 x breaker 16A 2p/C/10kA (hydraulics )
• 1 x breaker 10A 2p/C/10kA (lights)
• 4 x breaker 16A 2p/C/10kA (video screen)
• 1 x socket CE 16 (electronics)
• 1 x socket CE 16 (hydraulics)
• 1 x socket CE 16 (lights)
• 1 x Tour mate multiconnector female chassis ( supply video
)
• Earth connection point
•Emergencystop
• 32A CEE free socket (power from generator set)
• 32A CEE plug panel mount (supply to power distribution box) possibility to provide power from auxiliary device (grid)