Checklists and job aids
Initial installation
6 S8100 Installation and Upgrades
November 2003
5 For S8100, determine which equipment is required
and which is optional.
For a G600, see Comcodes for equipment used with
G600 on page 63.
For a CMC1, see Comcodes for equipment used
with CMC1 on page 346.
6 Install the system’s cabinet, making sure there is
adequate ventilation.
— Verify the carrier address ID on G600 or
CMC1 cabinets.
ID: _________________
— Mount the cabinets.
For G600, print a 7 × 11
″copy of the G600
mounting template provided on the CD.
For a G600, see Install and cable a G600 cabinet
on
page 65.
or
For a CMC1, see Install an S8100 with a CMC1
system cabinet on page 348.
7 Check electrical components.
— Check AC power.
— Ground power supply.
— Connect uninterruptible power supply (UPS).
— Disconnect AC power by pulling the AC
power cord from the appliance inlet.
— Connect cabinet and other grounds.
— Install coupled bonding connector.
— Connect the power cords.
For a G600, see Check AC power and ground for
G600 on page 72.
or
For a CMC1, see Check AC power and ground for
CMC1 on page 357.
8 Connect the cables.
— Install the Processor Interface cable.
— Install the system cables for multiple
cabinets, if necessary.
For a G600, see Cable a G600 system
on page 78.
or
For a CMC1, see Cable a CMC1 system
on page
367.
9 Install the S8100 patch panels (G600) or the main
distribution frame (CMC1).
For a G600, see Install G600 patch panels and
external modem on page 84.
or
For a CMC1, see Install CMC1 main distribution
frame (MDF) and external modem on page 370.
10 Install equipment-room hardware for G600 or
CMC1.
— Cross-connect the cabinet to the patch panels
for G600 or to the MDF for CMC1.
— Identify the allowed circuit packs.
— Install the circuit packs.
— Be sure that off-premises circuits have
protection from hazardous voltages and
currents.
— Install sneak fuse panels.
— For CMC1, label the MDF.
See:
DEFINITY Communications System Generic 1 and
Generic 3 Main Distribution Field Design (555-
230-630)
and
Install equipment-room hardware for G600
on page
86
or
Install equipment-room hardware for CMC1
on
page 372.
Installation tasks For more information