![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/8d/28d41ce2-930d-2a44-dde2-f18d5aabdba6/28d41ce2-930d-2a44-dde2-f18d5aabdba6-bg392.png)
Operational, Basic, and Advanced Parameters
A-178 41-001160-01, Rev 00, Release 2.3
IP Phone Administrator Guide
ACD Auto-Available Timer Settings
Parameter –
acd auto available
Auto Available
(in Web UI)
Aastra Web UI Basic Settings->Preferences
->Auto Call Distribution Settings
Configuration Files aastra.cfg, <mac>.cfg
Description Enables or disables the use of the ACD Auto-Available Timer.
Format Boolean
Default Value 0 (disabled)
Range 0 (disabled)
1 (enabled)
Example acd auto available: 1
Parameter –
acd auto available timer
Auto Available Timer
(in Web UI)
Aastra Web UI Basic Settings->Preferences
->Auto Call Distribution Settings
Configuration Files aastra.cfg, <mac>.cfg
Description Specifies the length of time, in seconds, before the IP phone status
switches back to “available.”
Format Integer
Default Value 60 (seconds)
Range 0 to 120 (seconds)
Example acd auto available timer: 60