Weslo WLTL21280 Treadmill User Manual


 
5. SYMPTOM: THE WALKING BELT IS OFF-CENTER WHEN WALKED ON
a. If the walking belt has shifted to the left, first remove the key and
UNPLUG THE POWER CORD. Using the allen wrench, turn the
rear roller adjustment bolt clockwise 1/4 of a turn. Plug in the
power cord, insert the key and run the treadmill for a few min-
utes. Repeat until the walking belt is centered.
b. If the walking belt has shifted to the right, first remove the key
and UNPLUG THE POWER CORD. Using the allen wrench, turn
the rear roller adjustment bolt counterclockwise 1/4 of a turn.
Plug in the power cord, insert the key and run the treadmill for a
few minutes. Repeat until the walking belt is centered.
STORAGE
Unplug the power cord when the treadmill is not in use.
Remove the bolt, washer, and nut from the lower end of each
handrail.
Remove the bolt from the upper end of each handrail.
Remove the bolt and washer from the lower end of the upright. Lay
the upright on the treadmill. Keep all bolts and washers in a secure
location.
Remove the batteries from the console and cover the treadmill
during extended periods of storage.
b
Remove
Remove
Remove
a
11
*WLTL21280-146358 5/4/00 11:24 AM Page 11