Weider WESY75742 Home Gym User Manual


 
TROUBLESHOOTING
19
ADJUSTING THE RESISTANCE
When the resistance setting changes, the motor will
be heard. To prevent damage to the motor, do not
pull any of the cables while the
resistance
setting
is changing. If a cable is pulled, the words
RELEASE HANDLES AND READJUST RESIST-
ANCE
AS DESIRED may appear in the main display
on the console.
If this message is displayed repeatedly but no cable
is being pulled, there may be too much tension on the
upper cable (A). Adjust the tension as described
below.
To decrease the tension on the upper cable (A), turn
the two 3/8” x 38mm Tension Screws (114) twice,
counterclockwise. Select the desired resistance set-
ting. Repeat this step if necessary
.
CLEANING THE BAR GUIDES
Over time, dust may build up on the Crossbar Guides
(15), causing a squeaking noise as the resistance
system is used. If this occurs, wipe off the Crossbar
Guides with a damp cloth and a mild, non-abrasive
detergent. Do not use solvents.
15
RECALIBRATING THE CONSOLE
To recalibrate the Console (67), first plug in the resist-
ance system (see PLUGGING IN THE RESISTANCE
SYSTEM on page 16). Then, press and hold the
NEXT button and the MOTORIZED WEIGHT
ADJUSTMENT + button for five seconds. When the
buttons are released, a number will appear in the
REPS display. Press the NEXT button again, then
press the MOTORIZED WEIGHT ADJUSTMENT +
button; this will start the recalibration process. This
may take a few minutes as the motor moves between
the lowest and highest resistance settings. When the
motor finishes, unplug the transformer from the 120-
volt outlet.
The Console (67) will be recalibrated. Use the resist-
ance system as described in the CONSOLE OPERA-
TION section, starting on page 16.
67
114
A