True Fitness 750EA Elliptical Trainer User Manual


 
Symptom Probable Cause Corrective Action Recommended Tools
SQUEALING /
SCREECHING
FROM
ALUMINUM
EXTRUSION
TUBES
750E, 750EA,
600EA.
Cleaning Aluminum
Extrusion Tubes
Checking Rollers
Moving Arm Travel
Remove aluminum extrusion tubes.
Clean tracks with general purpose
cleaner. DO NOT USE PETROLIUM
BASED CLEANERS – it will degrade
the rollers.
Clean roller.
-------
Check rollers for bumps and flat spots.
Do rollers spin freely?
If rollers do not spin freely – replace
rollers.
--------
Do the moving arms run straight down
the aluminum extrusion tubes?
If no – loosen nut on cubic joint.
If no help – replace moving arm
assembly.
Non- petroleum based
cleaner. (For example:
Simple Green)
Support Services 800-883-8783 Mon-Fri 8:30am-5:00pm Central Time Zone Fax: 636-272-7148