Symptom Probable Cause Corrective Action Recommended Tools
NO CONTACT
HEART RATE
600R, 600U
Control Panel
Defective Cables
Defective Handles
• Disconnect 7P6A and 7P6B from
control panel. 600U (Page 19) 600R
(Page 20). Check continuity between
7P6B and handle mounted heart rate
sensor plates of the following:
HRRR and pin 6 of 7P6B
HRRL and pin 5 of 7P6B
HRLR and pin 2 of 7P6B
HRLL and pin 1 of 7P6B
• Is there continuity?
• If yes – replace computer.
• If No- continue to the next step
--------
• Perform a contact and continuity check
on cable 600 12P, 600 12P coils upper
cables and the handle cables.
• Are cables OK? If No- Replace
defective cables. If Yes- continue on to
the next step.
--------
• Remove and carefully check all
connections to the contact plates.
• Reconnect loose connections.
• If connections OK – Replace handles.
Multi-meter
Support Services 800-883-8783 Mon-Fri 8:30am-5:00pm Central Time Zone Fax: 636-272-7148
Page 10