Seiko Group Cal. V110 Watch User Manual


 
11
English
English
10
GUIDELINE OF CHARGING TIME/ACCURACY
Environment/Lightsource (lux)
V110 V111/V117
A
(minutes)
B
(hours)
C
(hours)
A
(minutes)
B
(hours)
C
(hours)
General offices/ Fluorescent light (700)
50 16 140 180 60 -
30W20cm/ Fluorescent light (3000) 11 3.5 30 35 10 180
Cloudy weather/Sunlight (10000) 3 0.9 8 12 4 60
Fair weather/Sunlight (100000) 1 0.3 2 2 0.5 10
Expected life per charge from full
charge to stoppage
5 months 6 months
Loss/gain (monthly rate)
Less than 20 seconds when the watch
is worn on your wrist at a normal
temperature range (5 ºC to 35 ºC
)
Less than 15 seconds when the watch
is worn on your wrist at a normal
temperature range (5 ºC to 35 ºC)
Operational temperature range -5 ºC to 50 ºC -10 ºC to 60 ºC
A: Time to charge 1 day of power
B: Time required for steady operation
C: Time required for full charge
V114/V115/V116 V137 V147/V157/V158
A
(minutes)
B
(hours)
C
(hours)
A
(minutes)
B
(hours)
C
(hours)
A
(minutes)
B
(hours)
C
(hours)
180 60 - 110 16 - 110 25 -
35 10 180 30 4 90 30 6 120
12 4 60 8 1.2 30 10 2 35
2 0.5 10 1 0.1 10 2 0.4 9
12 months 6 months 10 months
Less than 15 seconds when the watch is worn on your wrist
at a normal temperature range (5 ºC to 35 ºC)
-10 ºC to 60 ºC
v
The above table provides only a general guideline.