Trouble Possible cause
The energy depletion forewarning function is activated.
If the second hand moves at two or five-second intervals
while you wear the watch everyday, the watch is in a
condition where it cannot get sufficient light, for instance,
the watch is concealed under a long sleeve shir
t.
The power save function has been activated while the
second hand stopped pointing to the 15-second
position or 45-second position.
The power save function is automatically activated
when the watch is not exposed to adequate light for a
certain period of time, to limit energy consumption.
The automatic hand alignment function was activated.
When the hand positions deviate to display incorrect
time as a result of the influence of various external
sources, the watch automatically corrects the hand
alignment itself.
The second hand moves at
two-second intervals.
The second hand moves at
five-second intervals.
The stopped second hand
pointing to the 15-second
position or 45-second position
started moving.
The watch hands advance
rapidly unless a button is
pressed. After the rapid
advancement is completed,
the watch resumes its normal
movement.
Hand
movement
TROUBLESHOOTING
Solution
Refer to “STANDARD CHARGING TIME” on page 11 to recharge the watch.
Be careful not to conceal the watch under a sleeve.
When taking the watch off, place the watch in as bright a location as possible.
(Make sure that the watch temperature is always kept below 60 ºC.)
Refer to “POWER SAVE FUNCTION” on pages 14-15.
If the watch moves at five-second intervals, immediately charge the watch.
For details, refer to “CHECKING THE CHARGING STATUS BY THE MOVEMENT OF THE
SECOND HAND” on page 12.
No operation is needed (this is not a malfunction).
For details, refer to “AUTOMATIC HAND ALIGNMENT” on page 19.