. With the help of a second person, carefully tip the
Uprights (20) and the Walking Platform (not shown) down
to the position shown. Make sure that the Extension
Legs (90) remain in place.
A
ttach the Extension Legs (90) with four Extension
Screws (87); start all four Extension Screws before
tightening them.
Next, attach the four Base Pads (81) to the base of the
Uprights (20) in the locations shown with four 1” Tek
Screws (82). Note: One replacement Base Pad may be in-
cluded. Use the Base Pad to replace any Base Pad that
becomes worn.
With the help of a second person, carefully tip the
Uprights (20) back to the vertical position.
87
20
82
87
90
90
82
2
81
81
3. Cut the tie securing the Pulse Wire (74) to the right
Upright (20). Next, hold the Pulse Bar Assembly (69) near
the crossbar on the Uprights. Connect the Pulse Wire to
the wire in the Pulse Bar Assembly.
The connectors
should slide together easily and snap into place. If
they do not, turn one connector and try again. Then,
insert the wires into the crossbar.
Open parts bag B. Attach the Pulse Bar Assembly (69) to
the crossbar on the Uprights (20) with four Pulse Bar Bolts
(13) and four Star Washers (67). Start all four Pulse Bar
Bolts before tightening them. Make sure that no wires
are pinched.
Crossbar
74
13
13
69
20
67
67
74
3
4. Cut the tie securing the wires to the right Upright (20).
Have a second person hold the console assembly near the
Uprights. Connect the Upright Wire Harness (73) and the
Pulse Wire (74) to the wires extending from the console as-
sembly.
The connectors should slide together easily
and snap into place. If they do not, turn one connector
and try again. Insert the connectors into the console as-
sembly. If necessary, remove the right accessory tray (not
shown) from the console assembly.
Connect the Upright Ground Wire (88) to the ground wire
extending from the console assembly. Make sure that the
wires are fully inserted into each other. Insert the ground
wires into the console assembly. Reinsert the right acces-
sory tray (not shown) into the console assembly if neces-
sary.
20
73
Console
Assembly
Ground
Wire
74
88
73
74
4