NordicTrack NTK1994.0 Treadmill User Manual


 
32
PROBLEM: The chest pulse sensor does not function properly
S
OLUTION: a
. If the chest pulse sensor does not function properly, see CHEST PULSE SENSOR TROU-
BLESHOOTING on page 10.
b. If the chest pulse sensor still does not function properly, the battery
should be changed. To replace the battery, locate the battery cover
on the back of the sensor unit. Insert a coin into the slot in the cover
and turn the cover counterclockwise to the “open” position. Remove
the cover.
Remove the old battery from the sensor unit. Insert a new CR 2032
battery
, making sure that the writing is on top. In addition, make sure
that the rubber gasket is in place in the sensor unit. Replace the bat-
tery cover and turn it to the closed position.
PROBLEM: The incline of the Incline Trainer does not change correctly or does not change when
iFIT.com CDs and videocassettes are used
SOLUTION: a. With the key in the console, press one of the Incline buttons. While the incline is changing, re-
move the key.
After a few seconds, reinsert the key. The Incline Trainer will automatically rise to
the maximum incline level and then return to the minimum level. This will recalibrate the incline.
Battery
Rubber
Gasket
Battery Cover
b
Battery
Cover