Error Codes
Table 3
Thank You for Purchasing a Bodyguard
®
T240 T260
Bodyguard
®
Fitness is dedicated to designing and manufacturing the finest fitness equipment available today.
This manual outlines information on warranty, assembly, operation of the unit, safety and basic maintenance checks for the
Bodyguard
®
T240–T260 treadmills.
When you require service for your T240–T260, always present the unit product model, serial number and date of purchase
to the Bodyguard
®
Dealer. The product model and serial numbers are located at the front of the machine. Now is a good
time to write the product model and serial numbers and related information in the space provided.
PROBLEM
• Error 1
• Error 2
• Error 11
• Error 12
• Error 21
• Error 22
• Error 23
• Error 31
•Elevation
Motor
Error
CAUSE / SOLUTION
Acceleration is too quick in an acceleration or reached speed phase.
Possible causes: Motor drive defective or user pushing on the running belt for too long.
Running belt not following the speed required in the reached speed phase.
• Possible causes: Deck too sticky. Walk on deck for 15 minutes at 4 mph.
• Motor drive board can be defective.
Check speed sensor or optical disk.
Acceleration is too fast during acceleration phase.
Possible cause: Defective drive board.
Acceleration is too slow during acceleration phase.
Possible causes: Deck too sticky.
Walk on deck for 15 minutes at 4 mph.
Speed sensor problem.
In a deceleration phase, the speed slows too fast.
Possible cause: Drive board defective.
• In a deceleration mode, the speed slows down too slowly.
Possible cause: Drive board defective, speed sensor problem.
There is an abnormal acceleration during deceleration.
Motor drive board is defective.
Acceleration is too quick under 2 mph.
Possible causes: Motor drive defective or user pushing on the running belt for too long.
Elevation motor values from potentiometer are out of range.
Possible causes: Elevation motor is defective or uncalibrated.
Perform an elevation calibration in the diagnostics menu.
Motor drive board can be defective.
Elevation Motor not functionnal.
Elevation Motor not connected.