Honeywell op10 Games User Manual


 
TABLE 1: WIRE GAGE SPECIFICATIONS SPECIFICATIONS
Electrical Characteristics:
Distance Gage 5 Conductor 6 Conductor
200 ft. (61m) 22 Alpha 1295C Alpha 1296C
300 ft. (91m) 20 Alpha 58126 Alpha 58126
500 ft. (153 m) 18 Alpha 58136 Alpha 58136
Note: Recommended cable is only a guideline, use any
manufacturer that meets the gage and shield specifications.
Power Supply Type:
Linear type Recommended
Operating Voltage Range:
5.0 – 16 VDC (Operational down to 4.25 VDC)
Maximum input current:
OP10, OP20, OP90
Standby: 35 mA
Read: 50 mA
OP30, OP40, OP45
HOW TO TEST AND OPERATE THE READER
Standby: 35 mA
The reader should be tested after wiring it to a power supply
and the host. Do this by performing the following steps:
Read: 100 mA
Tamper Output
Open collector, active low, max.sink current is 16 mA
1. Power up the reader. The LED and beeper will
activate three times. This indicates that the
reader is working properly.
Maximum Cable Distance to Host:
500 ft. (150 meters)
2. Present the appropriate type of ID card to the
reader. (See Table 2 for the correct card type
based on the reader model.) The LED will
momentarily flash green and a short beep will be
emitted. This indicates that the card was read
properly by OmniProx.
Card Read Distance:
See Table 2
Regulatory Approvals:
USA: UL 294 Listed & FCC Part 15 B
(Model OP90 is not yet UL listed)
Europe: CE Listed
3. After the card data is processed by the host, the
host can then turn the LED green or yellow.
Refer to the host description of the LED
operation if the reader LED is controlled by the
host.
Operating Temperature Range:
-25° F to 145° F (-31°C to 63°C)
Operating Humidity:
0 to 95% (non condensing)
Suitable for outdoor use
Dimensions:
OP10:
Table 2: Model Number vs. Feature Matrix
3.15” (80mm) L x 1.58” (40mm) W x 0.50” (12.8mm) D
Model
Number
UL Listing
Part #
Card
Type
Output
Format
Read
Range
(Max.)
*
OP10-FW AY-K10 HID Wiegand 3”
OP20-FW AY-J10 HID Wiegand 4”
OP30-FW AY-L10 HID Wiegand 5”
OP40-FW AY-H10 HID Wiegand 4”
OP45-FW AY-M10 HID Wiegand 4”
OP90-FW AY-Q10 HID Wiegand 1.5”
*Measured using HID Corp. Prox Card II (P/N 1326LSSMV)
or equivalent and the corresponding OmniProx reader
powered at 12 volts. Range also depends on electrical
environment and/or proximity to metal.
OP20:
4.73” (120mm) L x 1.65” (42mm) W x 0.55” (14mm) D
OP30:
5.71” (145mm) L x 1.69” (43mm) W x 0.79” (20mm) D
OP40:
4.33” (110mm) L x 2.96” (75mm) W x 0.59” (15mm) D
OP45:
3.5” (89mm) L x 3.5” (89mm) W x 0.59” (15mm) D
OP90:
4.72” (120mm) L x 3” (76mm) W x 1” (27mm) D
For additional information on the Wiegand™ Protocol, see
“Access Control Standard – Wiegand Card Reader Interface
SIA AC-01 (1996.10)” which can be purchased from SIA (see
www.siaonline.org)
OmniProx models with HID
compatibility are capable of reading
genuine HID cards under the terms o
f
a license agreement between HID
Corp. and the ADEMCO Group.
-2-