Casio 3022 Watch User Manual


 
Operation Guide 3022
2
3. When the timekeeping setting you want to change is flashing, use B and/
or D to change it as described below.
4. Press A to exit the setting screen.
Note
You also need to enter the Timekeeping Mode in order to configure the
following settings.
Power saving on/off (“To turn Power Saving on and off”)
Temperature, barometric pressure, and altitude units (“To select the
temperature, barometric pressure, and altitude units”)
Do this:
Press D
.
Use D (+) and B (–).
Press D
.
Use D (+) and B (–).
To do this:
Reset the seconds to
00
Change the hour or minutes
Toggle between 12-hour (1
2H
)
and 24-hour (
24H
) timekeeping.
Change the year, month, or day
Screen
12H
The year can be set in the range of 2000 to 2099. The day of the week is
calculated automatically in accordance with the date you set.
Barometer/Thermometer
This watch uses a pressure sensor to measure air pressure (barometric
pressure) and a temperature sensor to measure temperature.
You can calibrate the temperature sensor and the pressure sensor if you
suspect that readings are incorrect.
To take barometric pressure and temperature readings
Pressing B in the Timekeeping Mode or
Altimeter Mode enters the Barometer/
Thermometer Mode and starts barometric
pressure and temperature measurements
automatically.
It can take up to four or five seconds for the
barometric pressure reading to appear after
you enter the Barometer/Thermometer Mode.
Barometric pressure is displayed in units of
1hPa (or 0.05 inHg).
Temperature
Barometric
pressure
Barometric
pressure graph
Barometric
pressure
differential pointer
The displayed barometric pressure value changes to
xxxx
hPa (or inHg) if
a measured barometric pressure falls outside the range of 260 hPa to
1,100 hPa (7.65 inHg to 32.45 inHg). The barometric pressure value will
reappear as soon as the measured barometric pressure is within the
allowable range.
Temperature is displayed in units of 0.1°C (or 0.2°F).
The displayed temperature value changes to
xx
.
x
°C (or °F) if a measured
temperature falls outside the range of –10.0°C to 60.0°C (14.0°F to
140.0°F). The temperature value will reappear as soon as the measured
temperature is within the allowable range.
In some areas, barometric pressure is expressed in millibars (mb) instead
of hectopascals (hPa). It really makes no difference, because 1hPa = 1mb.
You can select either hectopascals (hPa) or inchesHg (inHg) as the display
unit for the measured barometric pressure, and Celsius (°C) or Fahrenheit
(°F) as the display unit for the measured temperature value. See “To select
the temperature, barometric pressure, and altitude units”.
See “Barometer and Thermometer Precautions” for important precautions.
Barometric Pressure Graph
Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
This watch takes barometric pressure measurements automatically every two
hours (at the top of each even-numbered hour), regardless of its current
mode. Measurement results are used to produce barometric pressure graph
and barometric pressure differential pointer readings.
The barometric pressure graph shows readings of previous measurements for
up to 30 hours. The horizontal axis of the graph represents time, with each dot
standing for two hours. The rightmost dot represents the most recent reading.
The vertical axis of the graph represents barometric pressure, with each dot
standing for the relative difference between its reading and that of the dots
next to it. Each dot represents 1hPa.
The following shows how to interpret the data that appears on the barometric
pressure graph.
A rising graph generally means improving weather.
A falling graph generally means deteriorating weather.
Note that if there are sudden changes in weather or
temperature, the graph line of past measurements may run
off the top or bottom of the display. The entire graph will
become visible once barometric conditions stabilize.
The following conditions cause the barometric pressure
measurement to be skipped, with the corresponding point on
the barometric pressure graph being left blank.
Barometric reading that is out of range (260 hPa to 1,100 hPa or 7.65 inHg
to 32.45 inHg)
Sensor malfunction
Not visible on
the display.
Barometric Pressure Differential Pointer
This pointer indicates the relative difference between the most recent
barometric pressure reading indicated on the barometric pressure graph, and
the current barometric pressure value displayed in the Barometer/
Thermometer Mode.
Pressure differential is indicated in the range of ±5 hPa, in 1-hPa units.
The barometric pressure differential pointer is not displayed when the
displayed current barometric value is outside of the allowable measurement
range (260 to 1,100 hPa).
Barometric pressure is calculated and displayed using hPa as the standard.
The barometric pressure differential also can be read in inHg units as
shown in the illustration.
Barometric pressure
differential pointer
hPa
values
inHg
values
Pressure
differential
examples in the
illustration are
indicated in 3 hPa/
0.1 inHg steps.
Current pressure
greater than most
recent measured
pressure
Current pressure
less than most
recent measured
pressure
About Barometric and Temperature Measurements
Barometric pressure and temperature measurement operations are
performed as soon as you enter the Barometer/Thermometer Mode. After
that, they are taken at five-second intervals.
You also can perform a barometric pressure and temperature measurement
at any time by pressing B in the Barometer/Thermometer Mode.
Altimeter
The watch’s altimeter uses a pressure sensor to detect current air pressure,
which is then used to estimate the current altitude based on ISA (International
Standard Atmosphere) preset values. You also can specify a reference
altitude, which the watch will use to calculate your current altitude based on
the value you specify. You can configure an altimeter alarm that sounds
whenever the measured altitude reaches a value you preset. Altimeter
functions also include storage of measurement data in memory.
Important!
This watch estimates altitude based on air pressure. This means that
altitude readings for the same location may vary if air pressure changes.
The semiconductor pressure sensor used by the watch for altitude
measurements also is affected by temperature. When taking altitude
measurements, make sure the watch is not subjected to temperature
changes.
To avoid the effect of sudden temperature changes during measurement,
keep the watch on your wrist in direct contact with your skin.
Do not rely upon this watch for altitude measurements or perform button
operations while sky diving, hang gliding, or paragliding, while riding a
gyrocopter, glider, or any other aircraft, or while engaging in any other
activity where there is the chance of sudden altitude changes.
Do not use this watch for measuring altitude in applications that demand
professional or industrial level precision.
Remember that the air inside of a commercial aircraft is pressurized.
Because of this, the readings produced by this watch will not match the
altitude readings announced or indicated the flight crew.