Braun A5 Home Gym User Manual


 
Page 15
Maintenance and Lubrication Schedule
Replace damaged parts and resecure as needed.
Apply Light Oil.
Resecure, replace or correct as needed.
Inspect lower fold arm pins (2), axles (2) and
bearings (8) for wear or damage and positive
securement
Remove pump module cover and inspect:
• Hydraulic hoses, ttings and connections for wear
or leaks
• Harness cables, wires, terminals and connections
for securement or damage
• Control board, circuit breaker, power switch and
lights for securement or damage
Repeat all previously listed inspection, lubrica-
tion and maintenance procedures at 750 cycle
intervals.
Consecutive
750 Cycle
Intervals
4500
Cycles
1500
Cycles
Resecure, replace or correct as needed
Use Braun 32840-QT (Exxon
®
Univis HVI 26)
hydraulic uid (do not mix with Dextron III or other
hydraulic uids). Check uid level with platform
lowered fully and roll stop unfolded fully. Fill
to within 1/2” of the bottom of the 1 1/2” ll tube
(neck).
Tighten, repair or replace if needed.
Tighten, repair or replace if needed.
Replace if needed.
Tighten or replace if needed.
Replace damaged parts and resecure as needed.
Apply Light Grease during reassembly procedures.
Replace if needed.
Tighten, replace or correct as needed
Apply Door-Ease or replace if needed. See Lubri-
cation Diagram.
Resecure or replace if needed.
Resecure, repair or replace if needed.
Check to see that the lift is securely anchored to
the vehicle and there are no loose bolts, broken
welds, or stress fractures.
Replace decals if worn, missing or illegible. Re-
place antiskid if worn or missing.
Inspect cotter pins on platform pivot pin (2)
Hydraulic Fluid (Pump) - Check level. Note: Fluid
should be changed if there is visible contamination.
Inspect the hydraulic system (cylinder, hoses, t-
tings, seals, etc.) for leaks if uid level is low.
Inspect cylinders, ttings and hydraulic connections
for wear, damage or leaks
Inspect outer barrier cylinder hose assembly (hose,
fasteners, connections, etc.) for wear, damage or
leakage
Inspect parallel arms, bearings and pivot pins for
visible wear or damage
Inspect parallel arm pivot pin mounting bolts (8)
Inspect platform pivot pins, bearings and vertical
arms for wear, damage and positive securement
Inspect upper/lower fold arms, saddle, saddle
support and associated pivot pins and bearings for
visible wear or damage
Inspect gas springs (cylinders - 4) for wear or dam-
age, proper operation and positive securement
Inspect saddle bearing (1) and saddle bearing but-
tons (2)
Inspect vertical arm plastic covers
Inspect power cable
Mounting
Decals and Antiskid
Perform all procedures listed in previous section also