
67
Palameter List
PARAMETERS
4
Commercial power supply
-inverter switch-over
135
Commercial power supply-inverter
switch-over sequence output
terminal selection
0, 1 1 0 148
136 MC switch-over interlock time 0 to 100.0 s 0.1 s 1.0 s 148
137 Start waiting time 0 to 100.0 s 0.1 s 0.5 s 148
138
Commercial power supply-inverter
switch-over selection at alarm
occurrence
0, 1 1 0 148
139
Automatic inverter-commercial
power supply switch-over
frequency
0 to 60.00Hz, 9999 0.01Hz 9999 148
Backlash
140
Backlash acceleration stopping
frequency (Note 7)
0 to 400Hz 0.01Hz 1.00Hz 86
141
Backlash acceleration stopping
time (Note 7)
0 to 360 s 0.1 s 0.5 s 86
142
Backlash deceleration stopping
frequency (Note 7)
0 to 400Hz 0.01Hz 1.00Hz 86
143
Backlash deceleration stopping
time (Note 7)
0 to 360 s 0.1 s 0.5 s 86
Display
144 Speed setting switchover
0, 2, 4, 6, 8, 10, 102,
104, 106, 108, 110
1489
Additional
functions
145 PU display language selection
148
Stall prevention operation level at
0V input
0 to 200% 0.1% 150% 84
149
Stall prevention operation level at
10V input
0 to 200% 0.1% 200% 84
Current
detection
150 Output current detection level 0 to 200% 0.1% 150% 153
151 Output current detection period 0 to 10 s 0.1 s 0 153
152 Zero current detection level 0 to 200.0% 0.1% 5.0% 154
153 Zero current detection period 0 to 1 s 0.01 s 0.5 s 154
Sub functions
154
Voltage reduction selection during
stall prevention operation
0, 1 1 1 84
155 RT signal activated condition 0, 10 1 0 155
156 Stall prevention operation selection 0 to 31, 100, 101 1 0 155
157 OL signal waiting time 0 to 25 s, 9999 0.1 s 0 157
158 AM terminal function selection
1 to 3, 5 to 14,
17, 18, 21
1192
Additional
function
160 User group read selection 0, 1, 10, 11 1 0 158
Automatic restart
after instantaneous
power failure
162
Automatic restart after
instantaneous power failure
selection
0, 1 1 0 96
163 First cushion time for restart 0 to 20 s 0.1 s 0 s 96
164 First cushion voltage for restart 0 to 100% 0.1% 0% 96
165
Restart stall prevention operation
level
0 to 200% 0.1% 150% 96
Additional
functions
168
Maker setting Parameters. Do not make setting.
169
Initial
monitor
170 Watt-hour meter clear 0 0 159
171 Actual operation hour meter clear 0 0 159
User functions
173 User group 1 registration 0 to 999 1 0 158
174 User group 1 deletion 0 to 999, 9999 1 0 158
175 User group 2 registration 0 to 999 1 0 158
176 User group 2 deletion 0 to 999, 9999 1 0 158
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Setting
Increments
Factory Setting
Refer
To
Page:
Customer
setting