My PRECOR 9.33 ha trouble, always STUCK KEY. I live at Bali, Indonesia. Please help. My email is setjo@ongkosanjojo.com

Asked by Setjo on 05/14/2014 2  Answers

ManualsOnline posted an answer 9 years, 11 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
5 Remove the keypad connector cable from the upper PCA. Restart the power up sequence, if the ERROR 5 is no longer present, the keypad is the cause. The keypad is typically part of the display housing. Replace the display housing to correct the problem. 2. Remove the keypad connector cable from the upper PCA. Restart the power up sequence, if the ERROR 5 is still present, the upper PCA is the cause. Replace the upper PCA to correct this problem. Most upper PCA’s are provided without software. Therefore, the software (chip) must be removed from the upper PCA being replaced and re-installed on the replacement upper PCA. 3. Wipe the surface of the touch sensitive display clean of all liquid. Restart the power up sequence, if the ERROR 5 is no longer present, the liquid was the cause.
Was this answer helpful?

Add Your Answer

Please Note: Do not submit personal information as it will be displayed online.