Owner’s Manual: Important Safety Instructions 4
IMPORTANT SAFETY INSTRUCTIONS
120 V and 240 V Units Designated for U.S.
Markets
The treadmill must be connected to a dedicated, grounded
circuit. A 15 amp dedicated circuit is required, but a
20 amp dedicated circuit is recommended. The power
outlet must have the same configuration as the plug. No
adapter should be used with this product.
240 V Units Designated for International
Markets
Your dealer must supply and verify that the treadmill is
equipped with an IEC approved 60320 C19 Inlet
connector, which has an IEC approved, SJT 60° minimum,
international color-code, 3 x 1.5mm 2 power cord. The
power cord must be equipped with a local connector that
can be plugged into an electrical outlet on a dedicated
circuit. No adapter should be used with this product.
Radio Frequency Interference (RFI)
Federal Communications Commission, Part 15
The treadmill has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference in a residential installation. The treadmill
generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the
owner’s manual instructions, may cause harmful
interference to radio communications.
If the treadmill does cause harmful interference to radio or
television reception, which can be determined by turning
the unit Off and On, you are encouraged to try to correct
the interference using one or more of the following
measures:
Reorient or relocate the receiving antenna for your TV,
radio, VCR, etc.
Increase separation between the unit and the receiver
(TV, radio, etc.).